Download PDF by L. Van Hoe, S. Van De Straete, H. Bosmans, G. Marchal: Advances in CT IV: 4th International Scientific User

By L. Van Hoe, S. Van De Straete, H. Bosmans, G. Marchal (auth.), Gabriel P. Krestin M.D., Ph.D., Gary M. Glazer M.D. (eds.)

ISBN-10: 3642721958

ISBN-13: 9783642721953

ISBN-10: 3642721974

ISBN-13: 9783642721977

There were persevered advances within the Siemens Somatom Plus CT expertise and functions over the past four years. advancements in scanning and software program have enabled nice strides to be made towards quick excessive solution, volumetric imaging and 3D monitors. Radiologists have swiftly carried out into those technical advances the scientific atmosphere for you to increase analysis and sufferer care. This e-book provides the sensible event of a global professional crew of radiologists and physicists with a few of the significant new advancements in spiral CT similar to dose relief, image-guided interventions, information postprocessing, and plenty of more.

Show description

Read Online or Download Advances in CT IV: 4th International Scientific User Conference SOMATOM PLUS CT Rotterdam, March 1998 PDF

Best international books

Get Computational Intelligence: Foundations and Applications, PDF

FLINS, initially an acronym for Fuzzy common sense and clever applied sciences in Nuclear technology, is now prolonged to Computational Intelligence for utilized examine. The contributions to the 9th within the sequence of FLINS meetings conceal state of the art learn, improvement, and expertise for computational intelligence platforms -- either from foundations and functions points-of-view.

L. Sanche (auth.), Dr. Alan R. Burns, Dr. Ellen B. Stechel,'s Desorption Induced by Electronic Transitions DIET V: PDF

This quantity within the Springer sequence on floor Sciences provides a up to date account of advances within the ever-broadening box of electron-and photon-stimulated sur­ face strategies. As in earlier volumes, those advances are offered because the court cases of the overseas Workshop on Desorption brought on by way of digital Transitions; the 5th workshop (DIET V) was once held in Taos, New Mexico, April 1-4, 1992.

Read e-book online Solar and Stellar Flares: Proceedings of the 104th PDF

Live performance at Dinkelspiel Auditorium 'An night of Songs and Arias' hosted through Dr Kip Cranna of San Francisco Opera, produced and directed by way of Elizabeth Tucker, and that includes soprano Ellie Holt Murray, mezzo-soprano Marsha Sims; tenor Richard Walker, and baritone David Taft Kekuewa, with piano accompaniment by way of Mark Haffner, employees trainer for San Francisco Opera.

Download e-book for kindle: Redefining the Process of Retirement: An International by W. Schmähl (auth.), Univ. Prof. Dr. rer. pol. Winfried

Earlier and destiny improvement in addition to percentages for influencing the method of retirement are mentioned, specifically results at the labour marketplace (supply and insist, behaviour of staff and corporations, pertaining to human source administration and occupational pensions), financing of social safety and source of revenue of staff.

Additional info for Advances in CT IV: 4th International Scientific User Conference SOMATOM PLUS CT Rotterdam, March 1998

Example text

J ip lJh :Jn tom I , , . • . Abd(l'IllI . nm I . """ , ~ " ' 500 C .. \ I o '':: ~ ooo c .... -- 'Hip Phantom' IGem x 36cm oval PMMA + in erts ~ 'Sboulder ~14em Phantom' x 40em elliptic water .. ' ":t. . . _ 50 _... · , , ,, "',"'-'-0 .. 150 o o 200 2'1) ___ . 1 50 'Abdomen Phantom' 20em x 30em oval water 'Quality Phantom ' 20em diameter water Fig. 2. Sketches of the phantoms used in simulations and physical measurements and associated attenuation values as a function of projection angle for the Somatom PLUS 4 at 120 kVp angle are shown in Fig.

Thus we measured noise in two regions of interest (ROIs at opposing sides of the phantom) close to the periphery and two ROIs close to the center of the phantom and averaged the values for each pair of ROIs. Spatial Resolution Measurements. , [1]). CT number profiles through the center of the bead yield the point spread function in all three spatial dimensions. After signal normalization, this point spread function direct1y converts into the slice sensitivity profIle for the z-direction, while its Fourier transform in the x-direction yields the MTF (within the scan plane).

We examined ten radiation therapy patients scheduled for CT as part of their routine work-up. For these patients four scan levels of the shoulder and upper thorax (the region where the greatest dose reduction was to be expected based on our prior experiments) were examined by single scans without and with tube current modulation. CT was performed without contrast medium to avoid ambiguities. All CT parameters were kept constant: 140 kVp, 5 mm slice thickness, 10 mm increment. Tube current was set to 206 rnA without current modulation and to 274 rnA maximum current for scans with current modulation.

Download PDF sample

Advances in CT IV: 4th International Scientific User Conference SOMATOM PLUS CT Rotterdam, March 1998 by L. Van Hoe, S. Van De Straete, H. Bosmans, G. Marchal (auth.), Gabriel P. Krestin M.D., Ph.D., Gary M. Glazer M.D. (eds.)


by Christopher
4.4

Rated 4.72 of 5 – based on 46 votes